Run9 BTOW HV Mapping Analysis - Part 2
Updated on Sun, 2009-03-08 21:55. Originally created by seelej on 2009-03-08 21:55.
Because there was not enough statistics taken in the first mod7 data set to determine the other towers that are swapped, another set with softID%6 was taken in order to determine the rest of the towers. The towers that need to be swapped are
389<->410
390<->411
391<->412
392<->409
633<->653
1026<->1046
1028<->1048
1120<->1140
1753<->1773
3679<->3678 (a swap with a "hot" tower->3678)
4549<->4569
A pdf file of all the towers that need to be swapped is attached to this blog entry. There may be other towers left, but it is become unlikely.
»