The second pass through both SMDE, SMDP was performed, learning from previous mistakes.
Main changes:
INPUT: 3M d-AU events from day ~336 of 2007.
All spectra were pedestals subtracted, using one value per strip, CAPS=123,124,125 were excluded. Below I'll use term 'ped' instead of more accurate pedestal residuum.
Method: fit slopes to ADC =ped+30,ped+100 or 5*sig(ped) if too low.
The spectra, fits of pedestal residuum, and slopes were QAed.
Note, BSMD rate 4 had old resistors in day 366 of 2007 and was excluded from this analysis.
This reduces # of strips from 18,000 to 15,750 .
cut# | cut code | description | # of discarded E strips | # of discarded P strips | figure in PDF1 |
1 | 1 | at least 10,000 entries in the MPV bin | 4 | ? | - |
2 | 2 | sig(ped) of gauss fit <~13 ADC ch | 13 | 11 | Fig 1 |
3 | 4 | position of mean gauss within +/- 4 ADC | 10 | 8 | Fig 2 |
4 | 8 | yield from [ped+30,ped+100] out of range | 513 | 766 | Fig 3 |
5 | 16 | chi2/dof<2.3 from slop fit | 6 | 1 | Fig 4 |
6 | 32 | slopeError/slop >10% | 5 | 0 | Fig 5 |
7 | 64 | slope in range | 19 | 6 | Fig 6 |
- | sum | out of processed 15,750 strips discarded | 635 ==> 4.0% | 789 ==> 5.0% |
Relative gain corrections for every eta bin
Method : find average slope per eta slice, fit gauss, determine average slope : avrSlope(iEta)
Gain correction formula is used only for extreme deviations:
Summary of BSMDE,P status tales and gains , ver 1.2