This algorithm searches for localized energy distributions in the barrel calorimeter, and will not run if the BTOW is not in the run.
This algorithm reads in 2 ints and 2 floats from run control:
[i0] debug
[i1] Random Accept Prescale
[f0] Et threshold for seed
[f1] Et threshold for cluster
The logic used is as follows:
Every tower with Et>f0 is added to a list. The list is then checked in order, summing the cluster around it and returning Accept if sumEt>f1
The Random Accept Prescale value sets the prescale for random accept, described elsewhere.
If debug>0 debug messages are printed.