2009.10.27 Jason EEMC geometry: effect of removing new SMD layers
Monte-Carlo setup:
- One photon per event
- Disabled/Enabled new SMD layers (EXPS EBLS EFLS) in Jason geometry
- EEMC only and Full STAR geometry configurations with LOW_EM option
(using Victor's geometry fix)
- Throw particles flat in eta (1.08, 2.0), phi (0, 2pi), and pt (6-10 GeV)
- Using A2Emaker to get reconstructed Tower/SMD energy
(no EEMC SlowSimulator in chain)
- Vertex z=0
- ~50K/per particle type
- Non-zero energy: 3 sigma above pedestal
Geometry configurations and notations (shown in the center of the plot):
- eemc-j: EEMC only with Jason geometry file
- full-j: Full STAR with Jason geometry file
- eemc-j-noL: EEMC only with Jason geometry file (disabled 3-new SMD layers)
- full-j-noL: Full STAR with Jason geometry file (disabled 3-new SMD layers)
Effect of removing SMD layers on SMD strips
Figure 1: Average number of SMD-u strips
Figure 2: Average number of SMD-v strips
Effect of removing SMD layers on sampling fraction
Figure 3: distribution of 1x1 sampling fraction
Figure 4: distribution of 2x1 sampling fraction
Figure 5: distribution of 3x3 sampling fraction
Figure 6: 1x1 sampling fraction vs. thrown energy
Figure 7: 2x1 sampling fraction vs. thrown energy
Figure 8: 3x3 sampling fraction vs. thrown energy