2010.01.18 EEMC response 2006 vs. 2009: typo in TPC volume size bug fix
Click here for previous study before TPC typo fix
Monte-Carlo setup
- Throwing one photon per event
- Full STAR y2006h/y2009a configurations
- Throw particles flat in eta (1.08, 2.0), phi (0, 2pi), and energy (5-35 GeV)
- Using A2Emaker to get reconstructed Tower/SMD energy (no EEMC SlowSimulator in chain)
- Vertex z=0
- ~50K/per particle type
- Non-zero energy: 3 sigma above pedestal
Before and after the fix comparison
Geometry configurations:
- y6h:10KeV:old (red) - y2006h with emc_10KeV option
- y6h:10KeV (black) - y2006h with emc_10KeV option, after TPC typo fixed
Figure 1: Pre-shower migration (1.2 < eta < 1.9)
y2006h vs. y2009a comparison after a TPC typo fix
Geometry configurations:
- y9a:10KeV (red) - y2009a with emc_10KeV option
- y6h:10KeV (black) - y2006h with emc_10KeV option
Figure 2: Pre-shower migration (1.2 < eta < 1.9): y2006h vs. y2009a