See this post from Alice for QCD sample rates
QCD and gamma-jet data samples are described here (filter parameters are listed below)
StEemcGammaFilter:: running the TEST mode (accepting all events). Set mFilterMode=1 to actually reject events
StEemcGammaFilter:: mConeRadius 0.22 mSeedThreshold 2.6 mClusterThreshold 3.6 mEtaLow 0.95 mEtaHigh 2.1 mMaxVertex 120
StEemcGammaFilter:: mCalDepth 279.5 mMinPartEnergy 1e-05 mHadronScale 1 mFilterMode 0 mPrintLevel 1
StChain:INFO - Init() : Using gamma filter on the EEMC
StChain:INFO - Init() : EEMC Sampling Fraction = 0.05
StChain:INFO - Init() : Seed energy threshold = 3.4 GeV
StChain:INFO - Init() : Cluster eT threshold = 4.5 GeV
StChain:INFO - Init() : Maximum vertex = +/- 120 cm
StChain:INFO - Init() : Running the TEST mode (accepting all events). Set mFilterMode=1 to actually reject events in BFC
BFC:INFO - setTowerGainSpread(): gain spread: 0; gain mean value: 1.1
Figure 1: Fraction of accepted events
Accept rate: fract. of generated events | |||
GammaJet | |||
pt bin | Bfc Filter | Pythia Filter | L2gamma Trigger |
pt=2-3 | 0.00646 | 0.09532 | 0.00656 |
pt=3-4 | 0.03042 | 0.2401 | 0.02772 |
pt=4-6 | 0.09438 | 0.42552 | 0.07568 |
pt=6-9 | 0.165984 | 0.54004 | 0.149137 |
pt=9-15 | 0.167329 | 0.559137 | 0.162972 |
pt=15-25 | 0.12486 | 0.45662 | 0.11744 |
pt=25-35 | 0.0562525 | 0.269499 | 0.0536273 |
Figure 2: False rejection (Y-axis scale is 10^-3)
False reject: fract. of generated events | |||
GammaJet | |||
pt bin | Bfc Filter | Pythia Filter | L2gamma Trigger |
pt=2-3 | 6e-05 | 0 | 0 |
pt=3-4 | 0.00016 | 6e-05 | 0 |
pt=4-6 | 0.0003 | 8e-05 | 0 |
pt=6-9 | 0.000261044 | 6.0241e-05 | 0 |
pt=9-15 | 0.000220884 | 6.0241e-05 | 0 |
pt=15-25 | 0.00028 | 0.00012 | 0 |
pt=25-35 | 0.000280561 | 0.000140281 | 0 |
Figure 3: Fraction of accepted events relative to Pythia filter accepted events
Accept rate: fract. of Pythia-filtered events | |||
GammaJet | |||
pt bin | Bfc Filter | Pythia Filter | L2gamma Trigger |
pt=2-3 | 0.0677717 | 1 | 0.0612673 |
pt=3-4 | 0.126697 | 1 | 0.105623 |
pt=4-6 | 0.221799 | 1 | 0.16991 |
pt=6-9 | 0.307318 | 1 | 0.26809 |
pt=9-15 | 0.299264 | 1 | 0.281882 |
pt=15-25 | 0.273444 | 1 | 0.244317 |
pt=25-35 | 0.20873 | 1 | 0.181217 |
Figure 4: False rejection relative to Pythia filter accepted events
False reject: fract. of Pythia-filtered events | |||
GammaJet | |||
pt bin | Bfc Filter | Pythia Filter | L2gamma Trigger |
pt=2-3 | 0.000629459 | 0 | 0 |
pt=3-4 | 0.000416493 | 0 | 0 |
pt=4-6 | 0.000517014 | 0 | 0 |
pt=6-9 | 0.00037183 | 0 | 0 |
pt=9-15 | 0.000287305 | 0 | 0 |
pt=15-25 | 0.000350401 | 0 | 0 |
pt=25-35 | 0.000520524 | 0 | 0 |