Hardware documents
This page is to organize hardware-related documents and pages.
Key logbooks
At the bottom of this page are "child pages" related to
Always useful: a very explicit set of pictures showing the mapping between WLS fiber ends and the tile number is at
drupal.star.bnl.gov/STAR/system/files/TileFiberMapping_0.pdf
Here is the logbook used for Supersector testing at Ohio State 30 June - 16 Oct 2017
Here is the
supersector construction logbook from OSU in summer 2017 -
PLEASE BE CAREFUL! I don't seem to be able to make this read-only. You should put the setting (upper right) to "viewing" to protect against unintended changes.
Clear Fiber Bundle Health/Status
A summary of all of the testing results of the Clear Fiber bundles since the start.
Criteria for passing (somewhat arbitrary, but based on results from the 3 bundles used in Run 17 that were deemed "good"):
- Average transmission of above -65%
- No single fiber in a bundle has transmission below -75%
Bundles to use in Run 18:
FB# |
Status |
Comments |
Average |
Max |
Full Sheet |
1 |
Healthy |
First bundle; repolished twice |
-63% |
-68% |
FB01 |
2 |
Healthy |
Results from 2nd test; avg unchanged from first test |
-55% |
-62% |
FB02 |
3 |
Healthy |
|
-54% |
-67% |
FB03 |
4 |
Healthy |
|
-63% |
-73% |
FB04 |
5 |
Healthy |
|
-62% |
-71% |
FB05 |
6 |
Healthy |
Repolished once |
-62% |
-68% |
FB06 |
7 |
Healthy |
|
-61% |
-73% |
FB07 |
8 |
Healthy |
Repolished 3 times |
-63% |
-72% |
FB08 |
9 |
Healthy |
|
-64% |
-71% |
FB09 |
10 |
Healthy |
|
-62% |
-68% |
FB10 |
11 |
Healthy |
|
-62% |
-73% |
FB11 |
13 |
Healthy |
Repolished 3 times |
-64.8% |
-73% |
FB13 |
14 |
Healthy |
|
-62% |
-73% |
FB14 |
15 |
Healthy |
|
-62% |
-73% |
FB15 |
16 |
Healthy |
|
-62% |
-73% |
FB16 |
17 |
Healthy |
|
-63% |
-70% |
FB17 |
18 |
Healthy |
|
-61% |
-69% |
FB18 |
19 |
Healthy |
|
-63% |
-68% |
FB19 |
20 |
Healthy |
Repolished twice |
-64% |
-69% |
FB20 |
21 |
Healthy |
|
-64% |
-72% |
FB21 |
23 |
Healthy |
Repolished once |
-63% |
-72% |
FB23 |
24 |
Healthy |
|
-63% |
-74.6% |
FB24 |
26 |
Healthy |
|
-62% |
-66% |
FB26 |
27 |
Healthy |
|
-57% |
-68% |
FB27 |
Failing Bundles that can still be used in Run 18 in an emergency:
FB# |
Status |
Comments |
Average |
Max |
Full Sheet |
22 |
Injured |
Failing upon retest. Not sure what's going on |
-61% |
-77% |
FB22 |
12 |
Injured |
Single fiber glows on both ends, possibly cracked |
N/A |
N/A |
N/A |
28 |
Injured |
Failing final test. Also even/odd difference of 6% |
-61% |
-78% |
FB28 |
Bundle Under Construction: FB25 (Broken splitter; construction not completed, but can be fixed and polished for the future if needed)
In summary, at the moment we have:
- 24 Passing Bundles (FB1-FB11, FB13-FB21, FB23-FB24, FB26-FB27)
- 3 Failing Bundles (FB28 has a fiber at -78%; FB12 has a fiber glowing on either end, so it was set aside. Has never been fully tested, but the glowing fiber was actually passing testing; FB22 failing upon retest; 2 fibers below -75%)
- 1 Incomplete bundle (FB25 had a tube splitter that broke. It can be fixed, polished and used, but of course should only be used as a last resort)
Google Spreadsheets for posterity:
Fiber by Fiber testing of every bundle: https://docs.google.com/spreadsheets/d/1rs-XOkZjJQz_nzMzTgH1vVVI4Ck12OCSJ_Dc_WHTaK8/edit#gid=0
Fiber Bundle Status Summary: https://docs.google.com/spreadsheets/d/1u5dWDUeguvjiPTBiH32b--NCzr-gS7l-ocCTeo5hBF0/edit#gid=0
FEE, SiPM, RX board Health Status
USTC has done a fantastic job of collecting and systematically posting their QA and characterization tests here. They cover
- FEE boards
- SiPM cards
- Receiver cards
Supersector and Tile Health/Status
This page records the health status of the 31 Supersectors. (Well, SS28 was dropped, so there are only 30, but we keep the numbering.)
Results of cosmic tests at OSU in Aug-Sept 2017 (4 SS in a stack), and BNL in Nov 2017 - Jan 2018 (3 SS in a stack).
The health sheets may be found here. (Also see "how to read a health sheet".)
Health status before run 2018 based on cosmic tests and cross-talk scan
SS |
status |
comments |
ADC spectra |
1 |
healthy |
hey, our much-maligned "first pancake" actually looks great! |
160131 |
2 |
healthy |
|
020304 |
3 |
healthy |
|
020304 |
4 |
healthy |
a bit less light than some others, but it worked well in run 2017 |
020304 |
5 |
healthy |
(taking another look at TT26 jan2018, to be sure, but it's fine) |
08050607 |
6 |
healthy |
(taking another look at TT26 jan2018, to be sure, but it's fine) |
08050607 |
7 |
healthy |
|
08181007 |
8 |
injured |
TT05 very low gain, probably unusable |
14081516 |
9 |
healthy |
TT03 has low gain |
06091417 |
10 |
healthy |
|
08181007 |
11 |
healthy |
|
09111213 |
12 |
healthy |
ADC spectra in test looked a little strange |
09111213 |
13 |
injured |
MAY be usable. X-talk b/t TT01,03; glued WLS fibers |
09111213 |
14 |
healthy |
|
06091417 |
15 |
healthy |
ADC spectrum for TT20 a little strange; see notes |
14081516 |
16 |
injured |
TT02 has very low gain. Had suspected paint on fiber end, but problem persists after cleaning |
161731 |
17 |
prob. healthy |
Joey should comment on X-talk issue; see health sheet |
161731 |
18 |
injured |
TT03 broke during construction. low gain. PERHAPS viable |
08181007 |
19 |
healthy |
|
17181920 |
20 |
healthy |
|
17181920 |
21 |
healthy |
TT21 ADC distribution a bit abnormal |
212930 |
22 |
healthy |
|
21222426 |
23 |
healthy |
|
252723 |
24 |
healthy |
|
21222426 |
25 |
healthy |
|
252723 |
26 |
healthy enough
|
TT03 has rather low gain, but probably usable. I'm comfortable with this in the experiment. |
21222426 |
27 |
healthy |
see notes for comments on TT24,25,27-31 |
252723 |
28 |
dead |
dropped and broken in pieces :-( |
|
29 |
healthy |
TT27 has low gain |
212930 |
30 |
healthy |
|
212930 |
31 |
healthy |
|
161731 |
According to this table we have
- 24 healthy (1-7, 9-12, 14, 15, 19-25, 27, 29-31) We'll use these in Run 2018.
- 2 healthy "enough" to use in experiment (17, 26)
- 4 injured: if we need to swap in, take them in the following order
- SS16 has low-gain TT02, but maybe usable. Take this first if needed.
- SS08 and SS18 each have one tile with low gain that are likely unusable.
- SS13 has cross-talk in small tiles due to glued WLS fibers. May be usable
- 1 dead (SS28). Don't use this one.
For the experiment, we need 24 SS, so we are in good shape:
100% of our 744 tiles are good!