Following is worked out by Valentino, Stephen <svalentino@bnl.gov>
Following runs are taken
Gate values are set to best values in following runs.
Run Number | QTB Discriminator Threshold | QTC_Discriminator_Threshold | |
1 | 18116044 | 16 (0x00F) = 8 mV | 64(0x03F) = 11 mV |
2 | 18116047 | 32 (0x01F) = 14 mV | 128(0x07F) = 28 mV |
3 | 18118021 | 24 (0x017) = 11 mV (linear interpolation) | 96(0x05F) = 19.5 mV (linear interpolation) |
Phase II | |||
4 | |||
Here is first analysis:
drupal.star.bnl.gov/STAR/system/files/EPD_ThresholdScan_Prashanth_05012017.pdf