- BEMC
- EEMC
- ETOF
- FCS
- FGT
- FGT. . . . . . . . . . I N S T R U C T I O N S
- FGT. . . . . . . . . . P H Y S I C S
- FGT. . . . . . . . . . S I M U L A T I O N S
- FGT. . . . . . . . . H A R D W A R E -- D E T E C T O R
- FGT . . . . . . . . . . A N A L Y S I S
- FGT . . . . . . . . . . C A L I B R A T I O N
- FGT . . . . . . . . . . D O C U M E N T S
- FGT . . . . . . . . . . DAQ
- FGT . . . . . . . . . . M E E T I N G S
- FGT. . . . . . . . . . H A R D W A R E -- E L E C T R O N I C S
- FGT. . . . . . . . . . H A R D W A R E -- S L O W C O N T R O L S
- FGT. . . . . . . . . . P H O T O - - G A L L E R Y
- FGT. . . . . . . . . . S O F T W A R E
- FGT. . . . . . . . . . V A R I A
- FGT. . . . . . . . . . x -T R A S H (node for recycling)
- FPD & FMS & FPS
- FTPC
- FTT
- HLT
- L3
- PMD
- PP2PP
- RICH
- Roman Pot Phase II*
- SSD
- SVT
- Slow Controls
- TPC
- TRG
- Trigger Detectors
- VPD
- test
FGT. . . . . . . . . . H A R D W A R E -- S L O W C O N T R O L S
Updated on Wed, 2012-02-15 11:44. Originally created by balewski on 2008-11-20 11:29.
Under:
Documentation of FGT Slow Controls Subsystem
(add child pages with specific documents below)
The manufacture's calibration for these flow meters is shown here. It is nonlinear as you can see. So, going from ~40 mm to >65 mm more than doubles the flow rate: it is well over 100 cc/min.
Scale reading Flow Rate
(mm) (cc/min)
---------------------- --------------
65 104.0
60 91.5
55 79.5
50 69.0
45 59.2
40 49.5
35 41.7
30 34.2
25 27.7
20 22.0
15 17.5
10 13.4
5 10.0
Regards,
Don
»
- Printer-friendly version