Calculation of error of A_L for LT=300/pb, for W± , eta=±[1,2], PT>20 GeV/c
- Input from RHICBOS , GRSV-STD model:
- The sign of pol cross section from RHICBOS has reversed convention, I have changed it to Medison convention.
hpol->Scale(-1.); - beam Pol=70%
- e+,e- reco efficiency is 70%, no PT dependence
- QCD background to W signal (B/S) contamination, after e/h algo no spin dependece
A B C ET_range
(EEMC 3x3_cluster)assumed w=backg/signal QCD eve
suppression needed for(B)20-25 GeV 5.0 +/- 20% - (for W+ or W-) 25-30 GeV 1.0 +/- 20% 1/539 or 1/520 30-35 GeV 0.8 +/- 20% 1/196 or 1/169 35-40 GeV 0.7 +/- 20% 1/43 or 1/ 69 40-45 GeV 0.6 +/- 20% 1/33 or 1/86 45-50 GeV 0.5 +/- 20% 1/119 or 1/289
(study 1 of S/B, A_L, LT=800/pb (Jan) section E)
after 3x3 EEMC cluster is found - eta of the lepton [1,2] (polarized beam is heading toward Endcap)
Formulas:
- Theory yields : unpol=sig0(PT) & pol=delL(pt) , S1=(sig0+delL)/2, S2=(sig0-delL)/2
- Measured yields N1, N2 , for 2 helicity states
- N1(PT)= eff*[ sig0 +P*delL + sig0 * w) /2
- N2(PT)= eff*[ sig0 -P*delL + sig0 * w) /2
- ALraw(PT)= 1/P (N1-N2)/ (N1+N2)
- V(ALraw(PT))= 1/P2 1/(N1+N2) <-- variance
- ALsig(PT)= (1+w(PT))* ALraw(PT)
- V(ALsig)=1/P2 (1+w)2*V(ALraw ) + V(w)*(ALraw)2
- dil=1+w
- QA= |(ALsig)/err(ALsig)| - must be above 3 for meaningful result
Fig 1, W+, eta=[1,2] , ideal detector
Fig 2, W+, eta=[1,2] , 70% W effi+QCD backg
Table 1, W+ , eta=[1,2] , LT=300/pb
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
---|---|---|---|---|---|---|---|---|---|
reco EMC ET GeV
|
reco W+ yield helicity: S1, S2 |
reco W+ unpol yield |
QCD Pythia accepted yield |
assumed B/S |
reco signal AL+err |
reco AL/err |
AL dilution: 1+B/S |
QCD yield w/ EMC cluster |
needed QCD suppression *) |
20-25 | 242 ,236 | 479 | 2397 | 5.0 | 0.019 +/-0.160 | 0.1 | 6.00 | ||
25-30 | 192 ,176 | 368 | 368 | 1.0 | 0.062 +/-0.105 | 0.6 | 2.00 | 198343 | 1/539 |
30-35 | 190 ,133 | 323 | 259 | 0.8 | 0.249 +/-0.109 | 2.3 | 1.80 | 50719 | 1/196 |
35-40 | 333 ,141 | 475 | 332 | 0.7 | 0.576 +/-0.098 | 5.9 | 1.70 | 14334 | 1/43 |
40-45 | 151,61 | 212 | 127 | 0.6 | 0.606 +/-0.132 | 4.6 | 1.60 | 4234 | 1/33 |
45-50 | 13,6 | 19 | 9 | 0.5 | 0.457 +/-0.393 | 1.2 | 1.50 | 1182 | 1/119 |
*) after 3x3 EEMC cluster is found, to obtain B/S from column 5
Fig 3, W-, eta=[1,2] , ideal detector
Fig 4, W-, eta=[1,2] , 70% W effi+QCD backg
Table 2, W- , eta=[1,2] , LT=300/pb
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
---|---|---|---|---|---|---|---|---|---|
reco EMC ET GeV
|
reco W+ yield helicity: S1, S2 |
reco W- unpol yield |
QCD Pythia accepted yield |
assumed B/S |
reco signal AL+err |
reco AL/err |
AL dilution: 1+B/S |
QCD yield w/ EMC cluster |
needed QCD suppression *) |
20-25 | 116,208 | 325 | 1626 | 5.0 | -0.403 +/-0.205 | 2.0 | 6.00 | ||
25-30 | 133,248 | 381 | 381 | 1.0 | -0.431 +/-0.112 | 3.8 | 2.00 | 198343 | 520 |
30-35 | 126,247 | 374 | 299 | 0.8 | -0.461 +/-0.107 | 4.3 | 1.80 | 50719 | 169 |
35-40 | 97,200 | 298 | 208 | 0.7 | -0.495 +/-0.115 | 4.3 | 1.70 | 14334 | 69 |
40-45 | 26,55 | 82 | 49 | 0.6 | -0.506 +/-0.203 | 2.5 | 1.60 | 4234 | 86 |
45-50 | 2,5 | 8 | 4 | 0.5 | -0.521 +/-0.617 | 0.8 | 1.50 | 1182 | 293 |
*) after 3x3 EEMC cluster is found, to obtain B/S from column 5
Fig 5, W+, eta=[-2,-1] , ideal detector
Fig 6, W+, eta=[-2,-1] , 70% W effi+QCD backg
Table 3, W+ , eta=[-2,-1] , LT=300/pb
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
---|---|---|---|---|---|---|---|---|---|
reco EMC ET GeV
|
reco W+ yield helicity: S1, S2 |
reco W- unpol yield |
QCD Pythia accepted yield |
assumed B/S |
reco signal AL+err |
reco AL/err |
AL dilution: 1+B/S |
QCD yield w/ EMC cluster |
needed QCD suppression *) |
20-25 | 316,168 | 484 | 2424 | 5.0 | 0.436 +/-0.175 | 2.5 | 6.00 | ||
25-30 | 235,137 | 373 | 373 | 1.0 | 0.375 +/-0.111 | 3.4 | 2.00 | 198343 | 531 |
30-35 | 189,132 | 322 | 258 | 0.8 | 0.252 +/-0.109 | 2.3 | 1.80 | 50719 | 196 |
35-40 | 255,223 | 479 | 335 | 0.7 | 0.094 +/-0.085 | 1.1 | 1.70 | 14334 | 43 |
40-45 | 109,102 | 212 | 127 | 0.6 | 0.048 +/-0.124 | 0.4 | 1.60 | 4234 | 33 |
45-50 | 10,9 | 19 | 9 | 0.5 | 0.027 +/-0.393 | 0.1 | 1.50 | 1182 | 119 |
*) after 3x3 EEMC cluster is found, to obtain B/S from column 5
Fig 7, W-, eta=[-2,-1] , ideal detector
Fig 8, W-, eta=[-2,-1] , 70% W effi+QCD backg
Table 3, W+ , eta=[-2,-1] , LT=300/pb
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
---|---|---|---|---|---|---|---|---|---|
reco EMC ET GeV
|
reco W+ yield helicity: S1, S2 |
reco W- unpol yield |
QCD Pythia accepted yield |
assumed B/S |
reco signal AL+err |
reco AL/err |
AL dilution: 1+B/S |
QCD yield w/ EMC cluster |
needed QCD suppression *) |
20-25 | 157,151 | 308 | 1544 | 5.0 | 0.024 +/-0.199 | 0.1 | 6.00 | 795943 | 515 |
25-30 | 187,180 | 367 | 367 | 1.0 | 0.029 +/-0.105 | 0.3 | 2.00 | 198343 | 540 |
30-35 | 187,179 | 367 | 293 | 0.8 | 0.033 +/-0.100 | 0.3 | 1.80 | 50719 | 173 |
35-40 | 151,144 | 295 | 206 | 0.7 | 0.033 +/-0.108 | 0.3 | 1.70 | 14334 | 69 |
40-45 | 41,40 | 81 | 49 | 0.6 | 0.026 +/-0.200 | 0.1 | 1.60 | 4234 | 86 |
45-50 | 3,3 | 7 | 3 | 0.5 | 0.012 +/-0.624 | 0.0 | 1.50 | 1182 | 301 |
*) after 3x3 EEMC cluster is found, to obtain B/S from column 5