Updated on Tue, 2008-10-14 13:35. Originally created by balewski on 2008-09-08 11:54.
INPUT:
- Run=9047029
- ideal gains
- db status tables, peds
- trigID=220520 = bht2-mb
Pio selection cuts:
- regular Alan's pi0 analysis.
- ene gamma1,2 >0.1 GeV
- pT di-gamma >3.0 GeV
- pt di-Gamma <10 GeV
Fig 1
TOP left: eta-phi distribution of di-gama,
TOP right : pt of di-gamma
Bottom left: invM vs. eta of di-gamma for PT in [3,7] GeV
Bottom left: invM vs. eta of di-gamma for PT in [7,10] GeV
»