Trigger Emulator Test run 7098001

Test trigger emulation on run 7098001

  • cvs co StRoot/StTriggerUtilities
  • Process run 7098001
  • Preselect trigger IDs 127611 and 127641 (bemc and eemc l2gamma)
  • Entry made in 2D histogram for every trigger ID seen
  • Entry made each time a given trigger emulator returns "true" (kYes or kDontCare)

Table 1 --  Online ID vs trigger emulator decision.  First column lists every trigger ID encountered during program execution.  Second column tabulates the number of times the trigger ID was encountered.  Third column shows the number of times that the BBC simulator resulted in a valid (kYes||kDontCare) trigger decision for that trigger ID.  Third (fourth) column displays the number of times the EEMC (BEMC) L0 simulator delivered an appropriate response.  And the last column indicates the number of times that the L2 trigger code reached a correct (kYes||kDontCare) trigger decision.


Online ID seen bbc eemc bemc l2
127271 804 804 804 804 804
127641 2436 2436 2436 2436 2436
127652 414 414 414 414 414
127221 1480 1480 1480 1422 1480
127611 2608 2608 2608 2591 2608
127212 1397 1397 1397 0 1397
127262 742 742 742 742 742
117602 368 368 368 0 368
127622 675 675 675 661 675
127571 6 6 6 0 6
127580 28 28 28 28 28
127585 8 8 8 0 8
127575 1 1 1 0 1
127551 17 17 17 17 17
117705 4 4 4 0 4
127501 3 3 3 2 3
117402 1 1 1 1 1