PPV Revision 1.29 +low pt- high luminosity fmsslow trigger evaluation
daq files are at:
/star/data03/daq/2008/068/9068124f
MuDst files are at:
/star/data05/scratch/rjreed/PPV2008Eval/MuDstPt100fmshigh
bfc options are:
'"DbV20080712 B2008a ITTF IAna hitfilt ppOpt VFPPVnoCTB l3onl emcDY2 fpd ftpc trgd ZDCvtx NosvtIT NossdIT Corr4 analysis OSpaceZ2 OGridLeak3D beamLine debug logger"
run with PPV revision 1.29 (includes PCT fix) + addition of tracks with 0.1<pt<0.2 which cross the central membrane. PPV code for this fix can be found at:
/star/data05/scratch/rjreed/PPV2008Eval/Vertex6
10975 Events
# Vertices, # Events
0,4035
1,5738
2,1079
3,118
1710 Events with PPV rank 0 + vpd
1260 Events match (within 20 cm)
359 Events with PPV rank 1 + vpd
147 Events match (within 20 cm)
5218 Events with PPV rank 0 + bbc
4621 Events match (within 60 cm)
963 Events with PPV rank 1 + bbc
661 Events match (within 60 cm)
1546 Events with PPV rank 0 + bbc + vpd
1074 Events match both vpd and bbc
Figure 1: vpd vz - rank 0 PPV vz
Figure 2:vpd vz - rank 0 PPV vz
Figure 3: Figure 1 fit with double gaussian where the mu = 0 for both, sigma 1 = 3, sigma 2 = 80
Figure 3 was fit from -200 to 200. Narrowing this range did not change the shape of the function (or its miss around +/- 10) significantly
Figure 4: Figure 2 with the same function as shown in figure 3.
Figure 5: vpd - vz for all ranked vertices. All = sum rank0 + rank1 + rank2
Figure 6: Figure 1 fitted with 3 gaussians with amplitudes p0,p3,p6 all fixed at an average of zero. The first gaussian has a sigma of 80, the second a sigma of 3 and the third was allowed to vary and it ended up at 25.
- rjreed's blog
- Login or register to post comments