Day Hour Fill PedRun# 1stLongRun#,nEv LastLongRun#,nEv nBadCr1 nBadCr2 nBadCr3 nBadCr4 nBadCr5 nBadCr6 nBadCr7 nBadCr8 nBadCr9 nBadCr10 nBadCr11 nBadCr12 Remarks(BSMD) Remarks(BPRS)
 73 11 AM  10368 none (using 10071072)  10073040,54 10073044,126 260 550 215  100  120  140  40 170 0 0 0 0

Note that no BSMD channels are masked out yet.

Eta RDO 1 softId 2200-2250 are especially bad.

Not much pedestal drift (MPVs are <0 more often than >0 though).

Bug in calculating RMS for BSMD channels: now fixed.

Bug caused BSMDP MPVs to be set equal to BSMDE MPVs, so the nBadCr numbers for this fill are not accurate: now fixed.

 Some channels have very high RMS, >10 and up to 20 or more in some cases (most have RMS~2).

Crate 20E has some structure in the 2D ADC plots.

 74  6 PM  10371 none (using 10071072)  10074007,47 10074025,89 190 325 280 130 128 122 45 144 0 0 0 0

 Still no masked out channels.

Eta softId 2200-2250 are definitely bad.

Almost no ped drift

74-75 5:30 PM 10373 10074059 1007467,147 10075018,175 205,165 315,275 150,115 70,65 35,70 95,110 40,25 110,100 0,0 0,0 0,0 2,21

Line in ADC vs. cap at ~100 in RDO 4?

Still no masking.

Oscillatory behavior persists in Phi RDO 7 (p. 65).

Something funny in SoftId 3150-3200, 3640-3720?

Still no masking.

76 3:15 AM 10382 10074059 10076027,95 10076067,70 268,222 312,318 208,193 100,130 137,143 92,114 38,66 155,480 0,0 0,0 0,0 19,20

Still no masking.

Eta softId 2150-2250 look even worse.

Either bad pedestals or significant drift for Eta softId 12750-12900, 13301-13351, Phi softId 300-450.

Between the first and last long run, Eta and Phi softId 16651-16800 died.  Most likely this means a dead module.  This explains the significant increase in dead channels over the course of the fill.

Oscillatory behavior now visible in parts of Phi RDO 0 (p. 44), 2 (p. 50), 3 (p. 53), 4 (p. 56), 5 (p. 59), 6 (p. 62), 7 (p.65).

Some pronounced sawtooth oscillations in RMS in Phi RDO 0, 1, 2, 4.

 Some channels now masked.

There appears to be a line in the ADC vs. cap plot for crate 20E at ADC~185.

Some channels in softId 3940-3980 seem to have displaced pedestals.

76-77 3:30 PM 10383 10074059 10076136,232 10076161,182 175,195 308,337 148,162 58,80 109,71 61,59 44,44 87,106 0,0 0,0 0,0 19,13

Still no masking.

Ped drift/bad ped/bad channel for Eta softId 300-400, 4200-4350, 13200-13350, 16050-16200, Phi softId 300-450, 13200-13350, 14100-14700, 15600-16050.

Eta softId 2150-2250 still pretty bad.

Oscillatory behavior in raw distributions and RMS persists (see above).

Band in ADC vs. cap plot persists (see above).

Potential bad channels in softId range 2650-2700.

Displaced pedestals in PSD 20E persist (see above).

77 6 AM 10386 10077044 10077014,133 10076104,238 107,173 177,252 90,123 29,46 104,63 29,53 24,48 53,63 0,0 1,0 25,18 0,2

Eta softId 8101-8150, 1801-1950, 12751-12900,  has badly displaced pedestals.

Oscillatory behavior in Phi crates persists and is even more pervasive (see above).

Band in ADC vs. cap for PSD-1E at ADC~180: could be associated with bad ped at 2660-2700.

PSD-20E pedestals look fine but there is still something strange: strong sawtooth pattern in RMS.

78-79 6 PM 10398 10078067 10078092,133 10079017,97 190,192 167,185 130,181 59,74 28,98 44,51 23,14 67,102 0,0 0,0 0,0 1,1

Significant Ped drift in Eta and Phi SoftId 13201-13350.

Oscillatory behavior in Phi Crate ADCs is gone (or at least less visible), but it persists in the RMS.

PSD-20E still looks funny though sawtooth pattern less visible (possibly drowned out by a few large-RMS channels).
79 3:30 AM 10399 10079021 10079042,112 10079086,91 324,254 236,272 116,164 55,66 39,79 50,40 37,25 82,81 0,0 0,0 0,0 1,1

Bad peds: Eta softId 8101-8150, 12751-12900, 13201-13350, Phi softId 13201-13350.

Phi RDOs: see previous fill.

see previous fill
 79-80 5:30 PM 10402 10079104 10079131,62 10079138,72 265,254 352,253 192,157 61,69 88,82 40,41 53,33 96,96 0,0 0,0 0,0 2,1 see previous fill: same bad softId regions, etc. see previous fill
80 2 AM 10403 10080006 10080020,88 10080020,88 168 274 117 60 76 54 36 74 0 0 0 0 see previous fills (though ADC oscillations in Phi RDOS are no longer visible) see previous fill
80 10 AM 10404 10080028 10080043,79 10080081,143 198,154 259,232 153,105 69,54 79,36 60,39 56,37 108,118 0,0 0,0 0,0 1,0

Bad peds for Eta softId 7401-7501, 13201-13350, 12751-12900, 12151-12300, Phi softId 13201-13350.

Eta softId 2150-2250 still looks horrible.

ADC oscillations in Phi RDOs are back in softId 4951-5100, 12151-12300.  Sawtooth oscillations in the RMS are also visible.

see previous fill: also, bad peds for softId 3540-3620.
80-81 11:30 PM 10407 10080085 10081013,78 10081055,98 268,204 527,276 139,154 88,93 121,72 66,53 58,59 85,106 0,0 0,0 0,0 0,6

Very bad peds for Eta softId 8160-8190.

Eta softId 1950-2250 was very bad for early runs (thus the large number of bad channels): the problem seems to have been corrected by the end of the fill, though 2150-2250 look bad as always.

Usual problems with 12750-12900, 13200-13350.

See remarks on Phi RDOs from previous fills.

Line in ADC vs. cap at ADC~190 has for PSD 20E has (maybe) reappeared.

Comments for previous fill also apply.

 81-82  6 PM 10412 10081076 10081117,129 10082093,82 187,178 174,231 140,470 48,95 67,126 53,57 52,61 62,410 0,0 0,0 0,0 0,0

 Ped-subtracted ADC vs. cap for RDO 4 has a surprising amount of counts for ADC <0.

Eta softId 8160-8190 still bad, 2150-2250 remains bad, 12750-12900 and 13200-13350 and Phi softId 13301-13350 still have problems, though not as serious.

New problems: Eta softId 13951-14050, 17350-17400, phi SoftId 10350-10450 has split peds.

Modules containing softId 5401-5550, and 16651-16800, died during the run. This explains the large increase in the number of dead channels.

Oscillations in Phi RDO ADC no longer visible but sawtooth oscillations in RMS remain.

 Line in ADC vs. cap not seen: otherwise, see previous comments about PSD 20E.
 82-83 10 PM  10415  10082119 10083013,92 10083056,153 203,202 300,241 187,198 69,55 109,79 50,58 24,39 105,104 0,0 0,0 0,0 1,0

 See previous fill's list of continuing problems (8160-8190 and 12750-12900 excepted).   The problems seen in eta 13951-14050 and phi 10350-10450 in the previous fill remain.

New problems: eta+phi softId 5401-5550 has all values 0 (note that this means that this problem does not show up in the bad channel counts), a couple of bad channels in eta 14520-14525.

Phi ADC oscillations still not visible but RMS oscillations remain and the spikiness of the ADC distributions that I assume they are associated with is even more pronounced.

 See previous fill.
84 12 AM 10426 10083155 10084010,103 10084022,104 176,187 245,216 120,162 46,71 58,97 53,68 28,20 108,68 0,0 0,1 0,0 1,1 Continuing problems remain, softId 5401-5550 still bad. see previous fill
84 7 PM 10432 10084070 10084076,68 10084083,157                         Problem with data used for monitoring, actual running not affected. Problem with data used for monitoring, actual running not affected.
85 12 AM 10434 10085003 10085017,150 10085039,110                         see previous fill see previous fill
85-86 5 PM 10439 10085052 10085107,114 10086046,238                         see previous fill see previous fill
87-88 10 PM 10450 10087102 10087126,123 10088031,137 198,156 crate off 178,148 57,60 60,44 50,56 20,20 375,375 0,0 0,0 0,0 0,0

Crate 2 is off for this fill.

Eta and Phi softId 5401-5550 have been masked out.

Eta softId 13200-13350, 12151-12300 have bad peds.

Eta and phi softId 16651-16800 have all peds 0.

ADC oscillations are back for Phi softId 12151-12300, 13201-13500.

Sawtooth oscillations remain for Phi ADC RMS.

See previous remarks about PSD-20E ADC vs. softId.
88 10:30 AM 10454 10088051 10088058,69 10088085,208 184,196 crate off 195,121 76,45 85,40 58,50 20,15 110,375 0,0 0,0 0,0 1,0

Crate 2 is still off.

Significant ped drift: Eta 8751-8800, 8901-8950, 8301-8350, 5251-5350, 3651-3700, 13201-13350, 12151-12300.

During the fill, softId 16651-16800 turned off (eta and phi).

See last fill's comments about oscillations in BSMDP.

See previous fill: also, lines in the ADC vs. softId plot for 3621-3650.
88-89 5:30 PM 10455 10088051 10088102,175 10089023,143 134,150 crate off 125,350 35,75 50,45 65,60 20,20 130,390 0,0 0,0 0,0 0,0

Crate 2 still off.

Ped drift: Eta 8751-8800, 8901-8950, 8301-8350, 6451-6600 (a problem with this module in eta and phi arises during the run leading to the increase in bad channels), 13321-13350.

SoftId 16651-16800 turned off during the fill again.

See previous fill about BSMDP oscillations, except that oscillations are no longer visible in 12151-12300.

See previous fill.
89 10 AM 10458 10088051 10089053,64 10089058,99 135,150 crate off 170,125 85,80 75,75 55,45 80,60 145,120 0,0 0,0 0,0 0,0

Crate 2 still off.

Only 4 capacitors appear to have been used for this fill, or at least for these two runs.

Eta softId 13201-13350 bad as usual.

Ped drift for eta 15151-15300.

See above for BSMDP oscillations, plus oscillations now visible for 4951-5100, 2251-2700, 9451-9600, 13051-13500, 13651-13800, 14701-14851, 15151-15300, 15751-15900, 16051-16200, 16651-16800

See previous fill, except that previously observed lines are not visible (may be artifact of low stats).
89-90 7 PM 10463 10088051 10090001,173 10090027,191 130,105 crate off 95,125 40,65 90,40 65,45 15,15 65,380 0,0 0,0 0,0 0,12

Crate 2 still off.

See previous long-standing problems with eta channels.

The softId 16651-16800 modules turned off during the run.

BSMDP ADC oscillations are mostly not visible, but RMS oscillations remain.

See previous fill: also, lines are back and some ped drift has appeared in PSD-20E, explaining the increase in bad channels.
90 6 AM 10464 10088051 10090037,103 10090047,164 160,170 crate off 145,105 55,65 60,60 55,45 15,15 400,400 0,0 0,0 0,0 0,0

Crate 2 still off.

16651-16800 modules still off.

See previous fill: little change.

See previous fill, except that lines are gone and ped drift has decreased (thus 0 bad channels) but is still visible.
90 11 AM 10465 10088051 10090074,117 10090111,102 155,140 crate off 120,130 55,75 70,80 50,60 20,15 90,390 0,0 0,0 0,0 0,0

Crate 2 still off.

Once again, softId 16651-16800 turned off during the run (eta and phi).

Otherwise, not much change from previous 2 fills.

Usual problems with PSD-20E being spiky and lines for softId 3621-3650.
91-92 9 PM 10471 10091080 10091090,103 10092050,161 239,172 218,176 148,91 81,55 80,63 84,76 44,23 106,385 0,0 0,0 0,0 0,0

Crate 2 is back on.

Usual bad peds Eta softId regions, plus 350-400 (newly restored thanks to Crate 2 being back).  However, 2150-2250 looks better than it used to.

SoftId 16651-16800 turned off during the run.

BSMDP ADC oscillation visible again, see e.g. 7351-7500, 8401-8550, 8701-8850, 6601-6750, 2251-2400, 9451-9600, 13051-13200, 13651-13800, 14701-14850, 15151-15300, 15601-15750, 15751-15900, 16051-16200.

Also, pedestal displacement for Phi softId 351-450, 9601-9750, 13201-13350. 12001-12150, 12451-12600, 13801-13950, 14101-14250.

See previous fill, except that the region with lines is now masked out.
93 8 AM 10478 10092061 10093006,207 10093083,93 164,187 253,464 107,167 55,88 40,98 93,76 35,32 415,435 0,0 0,0 0,0 0,0

SoftId 1801-2250 turned off during the run.

SoftId 16651-16800: off/bad peds?

Usual bad Eta softIds and Phi oscillations: see previous fill.

See previous fills
93-94 7 PM 10482 10092061 10093131,517 10094024,379 141,146 428,433 120,112 64,78 51,45 80,84 60,48 102,100 0,0 0,0 0,0 12,0

SoftId 1801-2250 still dead (eta and phi).

Eta softId 2401-2550 has a V pattern in the MPV.

Usual collection of eta softIds with some displacement and oscillating phi softIds: see previous fills.

See previous fills
94-95 12 PM 10486 10092061 10094063,371 10094099,180 120,170 262,323 90,141 34,79 31,54 68,123 50,26 62,105 0,0 0,0 0,0 0,0

Now that Crate 2 is back, Eta softId 2101-2250 is still bad, but in a different way, with significant pedestal drift.

Significant bad peds in Eta softId 17051-17100.

Usual problem areas from before: also, more BSMD ped drift.

See previous fills
95 4 AM 10490 10092061 10095022,61 10095052,217 245,157 408,285 276,169 97,97 97,38 80,88 70,20 180,116 0,0 0,0 0,0 2,0

Eta softId 2251-2400 has bad ped drift.

Starting to see significant ped drift.

See problem areas in previous fills.

See previous fills
95-96 7:30 PM 10494 10095080 10095121,73 10096027,107 216,164 259,180 185,154 131,109 73,56 56,60 30,28 140,108 0,0 0,0 0,0 0,0

Displaced peds for Eta softId 8671-8700.

Problem in Eta softId 2101-2250 has disappeared.

Usual problem areas from previous fills.

See previous fills
96-97 9 PM 10505 10096075 10097012,75 10097045,216 174,189 162,165 387,365 110,76 95,70 75,65 30,126 460,390 0,0 0,0 0,0 0,0

Eta softId 1470-1500, 6451-6600, 15301-15450, Phi softId 6451-6600 have bad peds.

Something is wrong with the module containing 16651-16800, but I'm not sure what: if it's the pedestals, they're not just displaced but are totally wrong.

Usual bad eta softId regions, less phi ADC oscillation but it's still visible in some places.

See previous fills
97 1 PM 10507 10096075 10097073,128 10097118,130 121,139 165,189 343,187 116,77 60,74 68,54 159,140 410,380 0,0 0,0 0,0 0,0

Bad peds for a few channels at Eta softId ~5370, 6571-6600.

16651-16800 is definitely off for this fill.

Most of the usual bad regions are still bad, though 6451-6600 looks mostly ok.

For BSMDP, see previous fill.

Nothing new
98 12 AM 10508 10096075 10098029,75 10098040,62 197,265 187,290 332,520 130,140 125,68 80,55 138,145 480,410 0,0 0,0 0,0 1,5

Module with softId 5251-5400 turned off during fill.

Signifcant ped drift for softId 6451-6600.

16651-16800 still off.

Less BSMDP ADC oscillation visible, may be a function of low stats.

Nothing new
99-100 8:30 PM 10525 10099142 10099186,66 10100017,64 174,226 253,125 176,167 139,95 75,70 93,82 78,90 130,475 0,0 0,0 0,0 1,1

More values at high and low ADC than expected for ADC vs. cap plot for RDO 7?  Low values are probably due to a dead module.

SoftId 901-1050, 4651-4800, 5251-5400, 16651-16800 appear to be completely off, all values are 0.

SoftId 16051-16200 turned off during the fill.

Split/bad peds for softId 15751-15900.

Bad peds for Eta softId 17371-17400, Phi softId 15661-15690

Nothing new
100 7:30 AM 10526 10099142 10100071,56 10100098,40 222,244 222,282 292,251 125,173 92,122 50,94 61,70 171,170 0,0 0,0 0,0 0,0

Eta softId 6451-6600 has bad peds.

Otherwise, see previous fill.

Nothing new
100-101 5:30 PM 10527 10099142 10100164,72 10101019,124 236,189 192,220 168,130 81,96 72,67 72,58 65,56 173,146 0,0 0,0 0,0 0,1

Eta softId 1801-1951 has bad peds.

Significant ped drift for phi softId 12151-12300.

Otherwise, see previous few fills.

Nothing new
101-102 2:30 PM 10531 10101047 10101060,58 10102003,177 166,158 253,248 180,81 132,105 64,44 60,45 108,63 133,50 0,0 0,0 0,0 0,0

Eta softId 1351-1500, 13951-14100 have bad peds, but 1801-1951, 6451-6600, 15751-15900, and phi 12151-12300 are fine.

Same dead modules.

Nothing new
102 2 AM 10532 10101047 10102033,72 10102066,117 210,169 321,283 302,203 104,94 69,65 50,33 56,40 72,62 0,0 0,0 0,0 0,0

Eta softId 6451-6600 is bad again.

Otherwise, see previous fill.

Nothing new
102-103 6:30 PM 10535 10102085 10102100,58 10103017,82 200,186 180,215 100,90 120,95 70,65 58,45 30,25 730,690 0,0 0,0 0,0 0,0

Eta softId 1351-1500, 6451-6600, 13951-14100, 15751-15900 are fine but 1501-1650, 17101-17250 are bad.

Modules 16051-16200, 16651-16800 were apparently on for pedestals but off during the fill (strange, because 16651-16800 had been pretty consistently off over the past few fills).

The other three off modules are still off.

Nothing new
103 6 AM 10536 10102085 10103027,94 10103041,93 181,146 235,227 74,110 90,95 73,93 46,56 37,33 145,420 0,0 0,0 0,0 0,0

Only module 16651-16800 turned off during the run.

Oscillations in BSMDP ADC spectra seem a little more pronounced than they have been for the past few run.

Otherwise, see previous run.

Nothing new