preparation to run 11 simulations (take0)
The following kumac , BFC , and rdMu.C setting should be used:
- STAR library: SL10j
- KUMAC
-
detp geom y2011
vsig 0.0 42.0
-
- BFC
-
"DBV20101215, tpcrs,y2011,MakeEvent,ITTF,NoSsdIt,NoSvtIt,Idst,BAna,l0,Tree,logger,Sti,VFPPVnoCTB,tpcDB,TpcHitMover,TpxClu,bbcSim,btofsim,tags,emcY2,EEss,evout,IdTruth,geantout,big,fzin,McEvOut,MiniMcMk,eemcDb,beamLine,clearmem,Corr4,OSpaceZ2,OGridLeak3D,sdt20101215.101112"
-
- rdMuDST
- dbMk->SetMaxEntryTime(20101010,0);
- dbMk->SetFlavor("Wbose2",bsmdeCalib");
- dbMk->SetFlavor("Wbose2",bsmdpCalib");
changes for Willie single -electron sample
- move 3 extra muons in eta from +0.75, to 4 muons at eta=-1.2 to avoid BTOW energy deposit
- extend eta range from [ .9 to 1.4.] to [0.5,1.5] - or more in the Barrel eta in [-0.2,1.5] ?
some evaluation of pilot W embedding in att 1
Groups:
- balewski's blog
- Login or register to post comments