SSD run 15 pp
Updated on Tue, 2015-10-20 09:59. Originally created by bouchet on 2015-02-15 10:10.
physics run : /star/data03/daq/2015/045/16045104/st_physics_16045104_raw_2000009.daq
Hot chip tables
Cut is set to 10% (= chips having occupancy > 10% are flagged as hot)
1) with (adc < 2* intrinsic_rms) cut
541 chips (on P and N sides) are removed
2) with (adc < 3* intrinsic_rms) cut
388 chips (on P and N sides) are removed
SSD monitor plots
The following plots are using offline/hft code over 2k events.
1) No hot chip table
charge matching and hit package
2) with hot chip table using (adc<3*intrinsinc_rms)
charge matching and hit package
»
- bouchet's blog