FPost ADC inspection for 2017 online monitoring output

This is an analysis of the ADC positions for all Channels of the FPost, which are currently being output into online monitoring, found here:

https://online.star.bnl.gov/fps2017/dkap7827/fpost/

Some brief notes:

Computer analysis has been done for runs 18053005 through 18059065 to check for dead channels, not recieving signal.
Visiual inspections have been done for runs 18059010 through 18059065 to check for any abnormalities currently affecting channels.

Channels that are dead are marked in red (unless otherwise noted, these channels have 0 entries).

Channels that have alarming behaviour are marked in yellow.

Channels that are mostly good, but might have slight issue, are marked in green, with notes next to them.

Channels that appear wholly good are marked in green, without notes.