Run11/Run13 QA

Select all produced runs with trigger setup pp500_production_2013 (BHT1)
üManually QA: Check RunLog / Shift Log information
üRun Status check:

    DAQ rates plots

    TPC continuous dead time / total dead time

    TOF unusable/off

üRemove runs with known detectors (TPC gas issue ,TOF issue…)

 

Run-by-Run auto QA

    Check iterms:

üVertex
üReference Multiplicity
üTOF beta
üBEMC tower Et

……

 

Full bad run list for BHT1 data at:

https://drupal.star.bnl.gov/STAR/blog/malong/run13qa

QA manual please refer to:

https://drupal.star.bnl.gov/STAR/blog/devika/2013/jul/19/run-qa- w-2013

Run13 BHT1 Bad Run List 
/////////////////////bad daq rate

  14077010,

  14083042,

  14084062,

  14109054,

  14118062,

  14123038,

/////////////////////tpc gas issue

  14100018,

  14100021,

  14100022,

  14100027,

///////////////////No mudst

  14084063,

//////////////////TOF issue

  14083036,

  14083022,

  14083021,

  14083020,

  14084015,

  14084062,

  14085008,

//14085019//BEMC and other

  14085023,

  14118062,

  14142134,

  14143001,

  14143081,

  14143089,

  14144037,

  14155087,

  14137059,

  14123038,

  14130068,

  14130074