Monitoring QA EPD plots

 Here you can find the most concerning (based on: https://online.star.bnl.gov/epd/ and https://dashboard1.star.bnl.gov/daq/EPD_UI/?EPD ) 

[most recent on the top]

25 July 2023

In run 24206005 we had some tiny problem with few channels - I guess one card. The run was short, so the fact that later it is ok I would not worry about it: 
https://online.star.bnl.gov/epd/Signal/24206/24206005.adc_Rg1_West.png

24 July 2023

Sometimes we are missing QA monitoring plots for some runs, good ones - not yet understood. But I checked them and they seems to be ok, just missing plots. I did the rainbow "scan" - looks ok! - attached TileByTile_24205007.pdf .

15 June 2023
Nothing new

07 June 2023

 E PP5TT10, E PP6TT10, E PP5 TT12, E PP5 TT14
We have the "hair comb" style - stuck bit?

https://online.star.bnl.gov/epd/Signal/24186/24186018.adc_Rg3_East.png

30 June 2023
No changes

28 June 2023
No changes

27 June 2023
First 5k run was not on the QA plots. Attached ADC plots run: 24177033
Look ok

26 June 2023
No changes.

25 June 2023
No changes.

24 June 2023
No changes.

23 June 2023

 
After break in printing QA monitoring plots I made some "rainbow plots" - attached. Looks ok. Today also QA monitoring ADC - no surprises. 

14 June 2023

Dead guys: WW PP1TT6 and W PP2TT10 still dead. Nothing interesting except of that.

06 June 2023

TILE  -  7 pattern info  -   GUI  -   online monitoring  plots. - links and comments

W PP1 TT6    - Mismatch! (zero on adc plot)      - Rmon abnormal, I=0.020muA   - high peak at very low adc - https://online.star.bnl.gov/epd/Signal/24157/24157001.adc_Rg2_West.png   
W PP2 TT10  - match patterns(OK!)                   - Rmon abnormal, I=0.020muA   - empty - https://online.star.bnl.gov/epd/Signal/24157/24157016.adc_Rg3_West.png
E  PP1 TT31  - Mismatch (zero on adc plot)       - I=8.330 muA                            - empty - https://online.star.bnl.gov/epd/Signal/24157/24157012.adc_Rg5_East.png
W PP2 TT27  - Mismatch  (zero on adc plot)      - I=3.880 muA                            - adc distribution present, I would say that there is relatively too much dark current? - https://online.star.bnl.gov/epd/Signal/24157/24157014.adc_Rg5_West.png
 


04 June 2023

DCS Control:
Two tiles W PP2TT10 PP1TT6 has Rmon "abnormal" -> same issue from the beginning

Yesterday I
 saw the high current in  East PP1TT1, not it is higher than yesterday: 10.220 muA - it is in 'grey" which I do not really understand. 

ADC

unstable card?
In one run 24155006 we had 4 channels W PP11 TT2,3,4,5 - just dark current
https://online.star.bnl.gov/epd/Signal/24155/24155006.adc_Rg1_West.png

Just dark current also in: 
[EDIT ] ->.  This is ok !!! W PP2 TT4 and W PP6 TT1 https://online.star.bnl.gov/epd/Signal/24155/24155006.adc_Rg1_West.png
W PP4 TT6 https://online.star.bnl.gov/epd/Signal/24155/24155015.adc_Rg2_West.png

empty :
E PP1 TT31 
https://online.star.bnl.gov/epd/Signal/24155/24155016.adc_Rg5_East.png. (same as previous days)
W PP2 TT10 https://online.star.bnl.gov/epd/Signal/24155/24155016.adc_Rg3_West.png (same as previous days)

 

03 June 2023

DCS Control:
Two tiles W PP2TT10 PP1TT6 has Rmon "abnormal" -> same as yesterday
One tile has high current ~10muA, East PP1TT1, the adc look ok, but has high dark current (top right plot): https://online.star.bnl.gov/epd/Signal/24154/24154001.adc_Rg1_East.png

ADC

Empty:

Dark current peak SAME AS YESTERDAY: W PP1 TT6  cr2 brd0x18 ch24 https://online.star.bnl.gov/epd/Signal/24154/24154002.adc_Rg2_West.png

02 June 2023

DCS Control:
Two tiles W PP2TT10 PP1TT6 has Rmon "abnormal" as on attached screen


ADC

Empty:

Dark current peak SAME AS YESTERDAY: W PP1 TT6  cr2 brd0x18 ch24  https://online.star.bnl.gov/epd/Signal/24153/24153013.adc_Rg2_West.png





01 June 2023

ADC

Empty: 

Dark Current only: