Vped scan vol 1 2024

 I ran the vped scan with local clock:

based on https://drupal.star.bnl.gov/STAR/blog/mstefaniak/Vped-test-05052023
- pedestal  at zeros : 25100025
- vped = -20, pedAsPhys: 25100026
- vped = -10, pedAsPhys: 25100027 
- vped =   0,   pedAsPhys: 25100031 
- vped =   10, pedAsPhys: 25100032  
- vped =  20,  pedAsPhys: 25100033
- vped =  40,  pedAsPhys: 25100034
- vped =  60,  pedAsPhys: 25100035
camac off 25100036
pedestals back: 25100037

Comparison for each tile for all the vped settings: here.
Fitted the new vped: here.

It is very odd, why we have so many camac crate off equal to zero?

additional test:
I set the vped for all of them vped = -50. And ran pedestal_rhic_clock_clean and then with the same settings pedAsPhys.
Expectation: all zeros. 
Results: 
we see some of the channels non zero while pedestal run (black) is zero for:
E PP10 TT30 (p71) - EQ1 b6 ch22
E PP9 TT28 (p77) = EQ1 b6 ch28
W PP10 TT8 (p86) = EQ1 b8 ch10
W PP5 TT6 (96) = EQ1 b10 ch0
W PP5 TT7 (97) = EQ1 b10 ch1
~ W PP7 TT23 (135) = EQ1 b11 ch23
E PP3 TT1 (186) = EQ2 b0 ch26
E PP1 TT2 (200)  = EQ2 b2 ch24
~ E PP4 TT23 (217) = EQ2 b6 ch15
E PP5 TT16 (218) = EQ2 b6 ch16
E PP5 TT22 (224) = EQ2 b6 ch22
W PP5 TT2 (234) = EQ2 b8 ch0
W PP5 TT5 (237) = EQ2 b8 ch3
W PP1 TT2 (247) = EQ2 b10 ch0
W PP1 TT4 (249) 
W PP5 TT10 (270)
W PP5 TT11 (271)  
W PP5 TT12 (272)  

...... many more