Run 11 TPC Sector Alignment Calibration
For Run 11, Tpc sector alignment calibration i have started taking all zero inital parameters . Subsequently in each iteration in local Db the parameter like "outerSectorLocalxShift" and "outerSectorRotationAngle" is changed .
Please, find here all sectors Residual_Y vs Local_Y co-ordinate as Y-axis and X-axis respectively.
http://www.star.bnl.gov/~nihar/run11_tpcCalib/
One can check my macros and procedure in this following path
/star/data07/TPC/nihar/calibration_run11
What I observed ?
- Excluding inner and outer 5 pad rows, there is still outer Y-residual are not Zero.
- Outer Residual are not flat.
- In each iteration, it is observed that there is no significant change in residual.
- Inner Residual are very much distorted.
discussing with Maxim: the possible reasons
- outer residuals flat are not probably due to the residual space charge and grid leak
Groups:
- nihar's blog
- Login or register to post comments