- pagebs's home page
- Posts
- 2017
- June (1)
- 2016
- 2015
- 2014
- December (2)
- November (1)
- October (2)
- September (4)
- August (1)
- July (2)
- June (2)
- May (3)
- April (2)
- March (2)
- February (2)
- January (1)
- 2013
- November (1)
- October (3)
- September (2)
- August (3)
- July (4)
- June (4)
- May (2)
- April (2)
- March (2)
- February (4)
- January (2)
- 2012
- December (2)
- November (3)
- October (2)
- September (1)
- August (3)
- July (3)
- June (6)
- May (2)
- April (3)
- March (3)
- February (2)
- January (2)
- 2011
- December (2)
- November (1)
- October (7)
- September (3)
- August (2)
- July (5)
- June (2)
- May (2)
- April (4)
- March (2)
- January (1)
- 2010
- December (2)
- October (4)
- September (1)
- August (4)
- July (1)
- June (2)
- May (2)
- March (4)
- February (2)
- January (2)
- 2009
- December (1)
- November (2)
- October (1)
- September (2)
- August (1)
- July (2)
- June (1)
- May (2)
- April (2)
- March (1)
- February (1)
- January (6)
- 2008
- My blog
- Post new blog entry
- All blogs
Run 9 200GeV Data / Simulation Comparison: Full RFF Simu Sample
Here I make a data / simulation comparison using the full RFF simulation sample ...
Figure 1: This figure shows the jet pt for data (Blue) and simulation (Red). The top row shows the spectra and the bottom row shows the data/simulation ratio. The left pannels show the L2JetHigh events, the middle pannels show the JP1 events, and the right pannels show the untriggered events.
Figure 2: This figure has the same layout as figure 1 but shows the jet eta spectra.
Figure 3: This figure has the same layout as figure 1 but shows the jet phi spectra.
Figure 4: This figure shows the pt vs pt for the two jets in the dijet event. The Y-axis shows the pt of the jet with the lower eta and the X-axis shows the pt of the jet with the higher eta. The left pannel shows data and the right pannel shows simulation. A plot showing the low pt jet pt vs the high pt jet pt can be seen here.
Figure 5: This figure shows the pt vs pt for the two jets in the dijet event. The Y-axis shows the eta of the jet with the lower pt and the X-axis shows the eta of the jet with the higher pt. The left pannel shows data and the right pannel shows simulation. A plot showing the low eta jet eta vs the high eta jet eta can be seen here.
Figure 6: This figure shows the phi vs phi for the two jets in the dijet event. The left pannel shows data and the right pannel shows simulation.
Figure 7: This plot shows the jet phi vs eta for both jets in the dijet event. The left pannel shows data and the right pannel shows simulation.
Figure 8: This plot shows the jet eta vs the z position of the event vertex for both jets in the dijet event. The left pannel shows data and the right pannel shows simulation. The same plot using the jet detector eta can be seen here.
Figure 9: This figure shows the jet pt vs the jet detector eta for both jets in the dijet event.
- pagebs's blog