Notes from Alice, etc:

Download of Alice's earlier BLOG:  See file attached below.

 

Code:

http://www.star.bnl.gov/cgi-bin/protected/cvsweb.cgi/StRoot/StEEmcPool/StEzSmdCal/

the bulk should be in the macros/ directory

you would get with

cvs co StRoot/StEEmcPool/StEzSmdCal

Alice

On 5/11/2010 9:57 AM, Alice P. Bridgeman wrote:
Hi all,

More links (copied from email from Scott):

-----------------------------------------------
The web page that best summarizes what was done for the 2006 mip
calibration is in the MIT 'locker', and can be accessed at

http://web.mit.edu/rhic-spin/public/eemc-bnl/calibration/run2006/cal2006/

I also gave a talk at the first EMC Calibration Workshop. The workshop
agenda with links is at

http://drupal.star.bnl.gov/STAR/conference/timetable/talk/12374

My talk on EEMC calibration is

http://drupal.star.bnl.gov/STAR/system/files/STAR-Calib-wksp.ppt

More later,
Scott

----------------------------------------------------

Alice
 

 

============

7jun2010:  Alice points to another link of EEMCl:  http://www.star.bnl.gov/Browser/EEMC/

 

June 16:  Ref:  http://www.star.bnl.gov/public/eemc/calibration/run2006/cal2006/   <== 2006 summary

Alice's summary from cal2006:

With SMD gains set at roughly 10% level, and with problem channels (SMD strips, towers, and pre/post layers) masked out, check for events with a "mip ID".  In each of the 12 sectors:

   * search for all strips with deposited energy < 0.5 MeV
   * require 1 or 2 adjacent strips to fire, with at least 7 non-firing strips on each side (e.g. 0000000xx0000000) � "mip candidate"
   * form intersections of mip candidates between the U and V planes, test if this position is inside tower fiducial cut (<0.7 cm from tower boundary)
   * if so:  for each of the four 'layers' (pre1, pre2, tower, post), increment histogram if the other three layers are all above pedestal � "mip ID"

Source = http://www.star.bnl.gov/public/eemc/calibration/run2006/cal2006/
Alice

================================