Preliminary EEMC Timing Curves by crate

Introduction

Runs taken for EEMC timing :

Run Number     ETOW TCD        ESMD TCD

12025060         25                      45

12025061         30                      55

12025062         35                      65

12025063         40                      75

12025064         45                      85

12025065         50                      95

12025066         55                    105

12025067         60                    115

12025068         65                    125

12025069         70                    135

12025070         75                    145

12025071         80                    155

12025072         85                    165

12025073           5                        5

12025074         10                      15

12025075         15                      25

 

Examined the dependence of sum of ADC-ped = 20 to ADC-ped = 100 versus the time delay.