Comments on Weihong's Runlist
Weihong's list nominally has 347 runs. The following 2 runs were not found to have any luminoscity information (according to the list obtained from Steve T.)
7133016 7145044
Using the latest CNI polarizations, 8 runs were found not to have valid polarization measurements,
7135016 7135018 7135019 7135022 7135023 7135024 7135025 7135028
Off the remaining 337 runs, 13 are in trig-d, 27 in trig-e, and 294 in trig-f, with the trigger sets defined on the last table of this blog. The number of BBC triggers per each is 3e+09, 2e+10, and 1e+11. The plots on Sept 13th used the trig-f set, which corresponds to 88% of the luminoscity.
Additionally, the following runs should probably be excluded, based on the run QA:
7132057 no trigger according to Jim D. 7139033 very low rates!! 7139034 very low rates!! 7139035 very low rates!! 7139036 very low rates!! 7139037 very low rates!! 7139040 very low rates!! (note: no TPC) 7145007 MAPMTs not usable according to runQA 7145044 bad bunch Xing according to Jim D. 7146017 ETOW not usable according to runQA
Groups: