sTGC work

 FindSignal.pdf is file when I am finding the signal in run 01105876 ADC thes is 15, and length is 5

FindSignal_PerEvent is file when I am finding the signal in run 01105876 ADC thes is 30, and length is 3

For sTGC voltage scan phase II

sTGC:3:0:vmon set to 1425V ~9:30 am and tripped few times at 5/7/2019 morning 
sTGC:7:0:vmon was rose to 1425V ~9:30 am and tripped once at 5/7/2019 morning

I think these run without trip can be used as 1425 V data.
and the runs taken at 7.5 morning are set to 1400 V but just one layer(sTGC:7:0:vmon) is used and the other layer had no HV.

run 20186053, in these run I didn`t see the sTGC included in the shift log but I see HV is set to 1425
run 20187001 stgc module 1 tripped.
run 20187002 20187003 20187004 20187005 physics run and stgc worked normally.
run 20187005 tripped.
run 20187007 20187009 looks sTGC run normally.
run 20187010 
Just noticed sTGC tripped, not sure when this happened.
run 20187011 20187012 20187013 sTGC worked normally
run 20187014 sTGC tripped.

run 20187015 Rosi did not record sTGC in shift log, I am not sure sTGC was included or not.

sTGC HV GUI user manual added

sTGC cable map ver1(from Prashanth) added

reference slide of how to divide the strip group can be found here and at Slide14