BTOF Hardware

 BTOF Hardware & Electronics

  • Bad Tray History (Aug. 20, 2021)
  • Tray 102 has a bad POS HV cable. It is behind the TPC support and cannot be repaired.

    Run 10 start  58

          end    10
    Run 11 start  25
          end    25
    Run 12 start  95
          end    95
    Run 13 start  46 106
          end    46 106
    Run 14 start  20  22  35 103
          end    20  22  35  78 103
    Run 15 start  38  41
          end    38  41
    Run 16 start 105
          end   105
    Run 17 start  36  45  80
          end    36  45  80  91 116
    Run 18 start   8  43 116
          end     2   8  40  43 116
    Run 19 start  30  34             (water leak on THUB NW trays 21-50)
          end    22  25  27  30  34  67  97
    Run 20 start  22  25  67
          end     8  22  25  48  64  67  88 101 118 119
    Run 21 start   8  22  48  64  67  88 101 118 119
          end     8  22  48  49  64  67  88 101 118 119

    pp500/510 history:

    Run  9  10 pb-1
       11  37 pb-1
       12  82 pb-1
       13 300 pb-1
       17 320 pb-1
       22 400 pb-1 (BUR)

    Current bad trays:

     8 - 8:0 bunch id error, 8:1 missing
    22 - no canbus
    48 - 48:0,1 missing
    49 - no canbus
    64 - TDIG 59 no response
    67 - may be ok now
    88 - 88:0 missing
    101 - 101:0 missing, 101:1 bunch id error
    118 - bad LV connection, seems ok now
    119 - 119:0 HPTDC 0x6 error

  • BTOF Electronics
  • Low Voltage Power Supplies:
    • Wiener PL512 Technical Manual
    • default SNMP community names for all TOF and MTD power supplies: {tof-pub, tof-priv, admin, guru}:

      [geurts@tofcontrol ~]$ snmpwalk -v 2c -m +WIENER-CRATE-MIB -c guru tof-lvps1 snmpCommunityName
      WIENER-CRATE-MIB::snmpCommunityName.public = STRING: "tof-pub"
      WIENER-CRATE-MIB::snmpCommunityName.private = STRING: "tof-priv"
      WIENER-CRATE-MIB::snmpCommunityName.admin = STRING: "admin"
      WIENER-CRATE-MIB::snmpCommunityName.guru = STRING: "guru"

    • power supply hostnames: see Tray Mapping documents
  • Network Power Switches:


TOF HV Hardware

This page is intended to host information about TOF's high voltage equipment.

A1534s (HV Supply Boards)

The A1534 is the HV Supply board that is inserted into our SY1527(MTD:SY4527 ).

Currently used boards(03/01/2016) for TOF + MTD: serial number and firmware version

TOF(counting from 0):
slot 1(-): 54, 3.01
slot 3(+): 56, 2.02
slot 5(-): 55, 2.02
slot 7(+): 57, 2.02

MTD(counting from 0):
slot 1(-): 66, 04.
slot 3(+): 69, 3.01
slot 5(-): 71, 04.
slot 7(+): 61, 03.
slot 9(-): 59, 3.01

Spare(-): serial number 58

Bad boards:
#59(Neg) - channel 3 bad (ch. 0-5) [occurred ~2/5/16 in SY4527 while in slot 1, was replaced with #66 on 2/17/16, then reinstalled in slot 9]

#66(Neg) - channel 3 bad (ch. 0-5) [occurred ~6/16/15 in SY1527LC spare while in slot 5, then installed and bl30,1 no data but reading back values when in slot 1 in 02/17/16]
-Email thread MTD BL 15-17 HV on MTDops 6/22-6/26/15.
-Not sure if this board was repaired between run15+16 and then failed again.

Spare:
#58(Neg) - possible bad channel 3 (ch.0-5). I think this was swapped in for #66 ~6/16/15(spare SY1257LC) and out for #71 ~2/02/16 (SY4527). Would have been in slot 5
Unaware of the positive spares available.

BTW: reoccurring issues on MTD BL15-17 from at least 1/17/2015 [slot 5 channel 3] and 5/11/2014, 1/31/2014...

Also some board repair history:

Forum: TOF sub-system forum
Re: HV boards in need for repair (Bertrand H.J. Biritz)
Date: 2010, Jul 27
From: W.J. Llope

Hi Bertrand, since there are so many bad boards now - Geary and I agree that we
should probably send them all in together a.s.a.p...

thanks, cheers,
bill

On Jul 26, 2010, at 7:34 PM, Bertrand H.J. Biritz wrote:

> Hi All,
>
> Just wanted to open the discussion on how to proceed with the HV board repairs.
>
> In total there are three boards in need of repair, with board 54 already having been sent in:
>
> Board 54: Channel 0 is arching [In use and fixed for TOF. Would explain the updated firmware.-joey ]
>
> Board 58: Channel 0 has ~130V offset and channel 3 no longer works [Could be a reoccurring issue with channel 3...?or explain why it failed, if it was the one swapped above-joey]
>
> Board 56: Channel 5 no longer works [In use on TOF--repaired.-joey]
>
> Board 58 is powering the East negative side of TOF (and MTD) while board 56 is for the East positive side of TOF (and MTD). We no longer have enough spares to make up for the lose of these boards.
>
> During last weeks TOF phone conference Geary said board 58 should be sent in for repair once the last noise rate data run was taken.
> Does the fact that an additional board is in need of repair change this and should board 56 be sent in at the same time as well?
>
> CAEN will be entering their three week summer holiday beginning of August. My unfounded guesstimation for getting the boards back is end of September at the earliest.
>
> Bertrand
>
>
> -------------------------------------------------------------
> Visit this STAR HyperNews message (to reply or unsubscribe) at:
> http://www.star.bnl.gov/HyperNews-star/get/startof/2362.html
>