Abstract:The committee review of the Installation and Test Subsystem Plan for installing and testing the baseline detector components of STAR in the Wide Angle Hall and associated facility buildings at RHIC. There is an Executive Summary of recommendations, plus comments on Critical Issues Findings, Scope and Interface definitions, Technical Resource requirements, Management responsibility, Common Installation Test Equipment, the Schedule and the Cost.
Keywords:integration IT Web page budget labor engineering support hardware installation