Update 02.17.2018 -- Run 9 pp Efficiency: Embedding
To continue the study of the tracking efficiency in run 9 pp, I calculated the track efficiency as a function of phi, eta, and pT from the run 9 dijet embedding. The particle level tracks were required to satisfy the following:
- |eta| < 1
- pTtrk > 0.2 GeV/c
And the detector level tracks were required to satisfy:
- Nfit > 15
- Nfit/Nposs > 0.52
- dca (global) < 1 cm
- |eta| < 1
- pTtrk > 0.2 GeV/c
No trigger was required, but the only events considered were required to have a primary vertex satisfying |Vz| < 55 cm and Vr < 2 cm at the detector level. Only bins with pTparton >= 5 were considered. The various efficiencies were fit in the same manner as in the post below. I wasn't anticipating the shape of the track pT efficiency, hence why I fit it with e(pTtrk) = e0 * (1 - exp(-sig * pTtrk)).
https://drupal.star.bnl.gov/STAR/blog/dmawxc/update-02092018-run-9-pp-efficiency-data
The "cut response" as a function of phi, eta, and pT are presented below. These are the ratio of (detector level) tracks after QA cuts to those before QA cuts.
- dmawxc's blog
- Login or register to post comments