hot Towers QA - run13 period 2
Similar to period one, the hot Towser QA has been done for run 13 period two.
1) Access the EMC information from MuDst files and plot the BEMC spectrum and EEMC spectrum to count the number of hits on each tower. ET> 2GeV
2) Find out the hot/warm tower. firstly, search the towers which contains more than 20% hits. secondly, search the towers where the number of hits is 10 time larger than the average hits.
Here are Lists contian the run numbers and hot Tower ID for Barrel and Endcap repectively.
Barrel hot tower table
Run range |
BEMC Tower ID |
14130069,14131033,14134062, 14134063,14135004,14135014-14135019,14145039,14145040 |
359 |
14130068,14130069,14131013,14131033,14134037,14134062, 14134063,14134065,14135003,14135004,14135014-14135019,14145039,14145040 |
360 |
14137067-14142017 (137) |
1786 |
14144126-14145011(6), 14145028-14145031 |
1789 |
14153045-14153049, 14154052,14154059,14156015-14158017 |
365 |
Endcap hot tower table
Run range |
EEMC Tower ID |
14134007-14135022 |
342 |
14146008,14146052-14146055,14146060,14146066 |
88 |
14137017-14161020 |
549 |
14145040 |
546,547,549 |
14148081 |
702 |
14138042 |
318 |