Operations
Welcome to the STAR Operations Home Page
Daily operations meeting at 10am on Zoom: https://bnl.zoomgov.com/j/1603605873pwd=NVk1aWs2OW5yb01rTzNtODhiaUJtQT09
(Zoom Meeting ID: 160 360 5873 Passcode: 110789)
Communications for STAR control room /shift/operation related on Zoom: https://bnl.zoomgov.com/j/1605144596?pwd=N3ExMDh3Q2txK0FxYTBVTzg4N0hHZz09
(Zoom Meeting ID: 160 514 4596 Passcode: 726787)
Select the menu for information relevant to STAR Operations.
-
STAR Operations Procedures
- STAR Detector Readiness Checklist for Run21 7.7 GeV collisions (Current Version 2/18/2021)
- STAR Detector States for Run21 7.7 GeV collisions and Fixed Target (Current Version 3/17/2021)
- STAR Detector Readiness Checklist for Run21 Fixed Target (Current Version 3/3/2021)
- STAR Detector Readiness Checklist for 26.5 GeV FXT during CeC Time (Current Version 8/27/2020)
- Checklist for recovering from power failure(Current Version 8/17/2020)
- Detector Operator Station Setup (Updated 12-Mar-21)
- TPC Operations
- EPD (updated 7-Mar-18)
- BEMC (updated 18-Jan-19)
- EEMC (updated 24-Feb-18)
- EMC (updated 17-Dec-02 - this link is dead
- GMT (updated 15-Jan-19)
- Magnet (updated 17-Dec-02)
- Reference Plots
- Offline QA
- Online server
- Online Q/A Plots (Jevp Plots) (updated 6/16/2020)
- Current RunControl/DAQ issues (updated 3/15/2021)
- Run Control (updated 3/2/18)
- Procedure for including ETOF in runs while ramping up/down
- Slow Controls Procedures
- TOF/MTD/eTOF General Instructions (updated 03-Feb-2021)
- TOF Freon Bottle Swithcover Procedure
- TOF Power Cycle Procedure
- TOF HVIOC Restart Procedure
- TOF LVIOC Restart Procedure
- MTD Power Cycle Procedure
- MTD HVIOC Restart Procedure
- MTD LVIOC Restart Procedure
- Canbus Restart Procedure (updated 30-Mar-18)
- eTOF General Instructions (updated 09-Feb-2021)
- eTOF Supplemental Instructions (updated 03-Feb-2021)
- "eTOF Hit Position" vs "ETOF Hit Local Y"
- Solve MTD (eTOF) Isobutane Fraction Alarm Instructions
- Handle TOF LV alarms
- Trigger (updated 5-Mar-13)
- BBC/ZDC/VPD LeCroy1440 Communication Problem Procedure
- V124 and STAR global timing
- C-AD Procedure for Exciting the STAR Magnet (normal user cannot connect to this)
- C-AD Procedure for Bypassing the STAR Safety Interlock Systems (normal user cannot connect to this)
- List of Authorized People for the STAR SGIS Interlock System (normal user cannot connect to this)
-
STAR Operations
- STAR Safety Review for Run19 (not a link)
- STAR FY19 Environmental emissions.doc (not a link)
- Procedures for detectors not currently available
- FPS/FPOST (updated 04-Apr-17)
- FMS UV curing procedure (updated 21-Mar-17)
- RP
- RP Slow control instructions (updated 2017-Mar-10 )
- Roman Pots Operations manual (updated 2017-Jun-24)
-
STAR Technical Support Group
- STAR Expert Call list (updated Feb. 22, 2021)
Groups:
- Printer-friendly version
- Login or register to post comments