BEMC
Run-12 pp-500 BEMC Calibartion
Updated on Tue, 2015-09-22 12:43. Originally created by posik on 2015-08-19 13:12. Under:200 GeV Calibration
Updated on Tue, 2014-04-08 21:24. Originally created by jkadkins on 2014-04-08 21:24. Under:This calibration was done with the 200 GeV proton-proton data collected in 2012. The calibration trees are backed up on HPSS and can be found here:
Run 12 BTOW Calibration
Updated on Sat, 2014-03-29 00:55. Originally created by jkadkins on 2014-03-29 00:55. Under:This is parent page that will hold all informationa about the run12 BEMC gain calibration
5) Absolute Gain Calibration with Electrons
Updated on Fri, 2014-01-17 08:09. Originally created by aohlson on 2013-11-18 04:44. Under:Electron calibration
4) Relative Gain Calibration with MIPs
Updated on Fri, 2014-01-17 08:06. Originally created by aohlson on 2013-11-18 04:43. Under:Getting Started
1) The code needed to perform the gain calibrations can be checked out from CVS and compiled. In your working directory, do:
2) QAing the Pedestal/Status Tables
Updated on Tue, 2013-11-19 04:03. Originally created by aohlson on 2013-11-18 04:40. Under:Once the ped/stat tables have been generated, they must be QAed. I do the QA in two parts:
3) Uploading Pedestal/Status Tables to the Database
Updated on Mon, 2013-11-18 08:07. Originally created by aohlson on 2013-11-18 04:39. Under:Once the ped/stat tables have been QAed satisfactorily, the values need to be uploaded to the database.
1) Generating Pedestal/Status Tables
Updated on Mon, 2014-11-24 15:47 by jkadkins. Originally created by aohlson on 2013-11-18 04:34. Under:Getting Started
BTOW - Calibration Procedure
Updated on Mon, 2013-12-16 03:49. Originally created by aohlson on 2013-11-18 04:31. Under:Here you will find the calibration procedure for the BTOW (as of 2013).
Additional documentation about BTOW gain calibrations in previous years can be found here:
BEMC Online Trigger Monitoring
Updated on Fri, 2013-06-07 15:40. Originally created by stevens4 on 2013-06-07 15:37. Under:Yearly Timestamp Initialization
Updated on Fri, 2011-11-04 14:54. Originally created by stevens4 on 2011-11-04 10:19. Under:Yearly Timestamp Initialization
BSMD Status Table in run10 AuAu200GeV runs
Updated on Wed, 2011-02-16 18:29. Originally created by xwq1985 on 2011-02-16 18:03. Under:==========
We started this task by looking at BSMD in Run 10 with some MuDst files, and found the pedestals probably need to be QA-ed as well.
Run 10 BSMD Calibrations
Updated on Tue, 2011-02-15 14:59. Originally created by stevens4 on 2011-02-15 14:59. Under:Parent page for BSMD Run 10 Calibration
BSMDE 2010 mapping problem and solution
Updated on Mon, 2010-12-27 11:23. Originally created by stevens4 on 2010-12-22 12:15. Under:All the details of the mapping problem can be found in this ticket. This page is a summary of the problem, solution, and
Final Run 9 200 GeV BSMD Status
Updated on Wed, 2010-11-03 17:06. Originally created by wleight on 2010-11-03 17:06. Under:Final Run 9 BSMD Absolute Calibration
Updated on Wed, 2010-11-03 17:00. Originally created by wleight on 2010-11-03 17:00. Under:The Run 9 BSMD absolute calibration was made using few-GeV TPC-identified electrons from pp500 running, and has two pieces. The first is a new CALIBRATION table in the database whic
14 200 GeV Calibration
Updated on Fri, 2010-07-09 17:06. Originally created by mattheww on 2010-04-12 10:56. Under:I selected 634 runs for calibration from the Run 9 production, processing over 300M events.
BEMC_FEE_Repairs (BSMD)
Updated on Wed, 2010-09-08 14:19. Originally created by wwjacobs on 2010-04-05 09:27. Under:Here (below) are the BSMD FEE repair record spreadsheets from Phil Kuczewski.
The one with label "BEMC_FEE_Repairs-2010.xls" is most recent, including repairs in 2010
Hardware
Updated on Thu, 2010-05-06 14:16. Originally created by wwjacobs on 2010-04-05 09:17. Under:13 Updating Calibration using the latest L2W production
Updated on Sun, 2010-01-24 14:27. Originally created by mattheww on 2010-01-22 15:44. Under:I recalculated the Barrel calibration using the latest L2W production, which relies on the latest TPC calibration.