2006 Gain uniformity
Updated on Thu, 2008-05-15 14:04. Originally created by mattheww on 2008-05-15 14:04.
Under:
Using the gains we calculated for 2006 tower by tower from the MIPs and then corrected with the electron eta rings, I calculated how it differed from the ideal gain assuming containment of an EM shower with 60 GeV ET. After removing bad towers, we can fit the distribution of this ratio to a gaussian and we find there is approximately a 6% variation in the gains.
»
- Printer-friendly version
- Login or register to post comments