- BEMC
- EEMC
- 2007 run, hardware changes
- 2008 run preparation
- Calibrations
- 2007 EEMC Tower Gains
- Calculating EEMC pedestal and status tables
- Calculating EEMC tower ideal gains and expected MIP response
- EEMC Calibration Docs
- EEMC Tower Swaps
- Overview for generating EEMC pedestals and status tables
- Producing ADC distributions for the EMCs from raw DAQ files
- Run 10 EEMC Calibrations
- Run 11 EEMC Calibrations
- Run 12 EEMC Calibrations
- Run 13 EEMC Calibrations
- Run 15 EEMC Calibrations
- Run 17 EEMC Calibrations
- Run 8 EEMC calibrations
- Run 9 EEMC calibrations
- Uploading EEMC Pedestal, Status and Gain Calibrations to the DB
- EEMC Maintenance/Operations Documents
- Endcap Geometry
- Endcap Geometry update (2009)
- Log of tower base and fee issues
- eemc as-built info and proto tests
- emc2-hn minutes (by Jan)
- how-to by Jan
- slow controls archive viewer
- trash
- ETOF
- FCS
- FGT
- FPD & FMS & FPS
- FTPC
- FTT
- HLT
- L3
- PMD
- PP2PP
- RICH
- Roman Pot Phase II*
- SSD
- SVT
- Slow Controls
- TPC
- TRG
- Trigger Detectors
- VPD
- test
EEMC Gain Calibration Using MIP Run9
Updated on Thu, 2015-04-30 15:19. Originally created by tinglin on 2014-11-21 14:08.
Under:
Dead channels:
SMD strips:
03V112, 03V258, 05U212, 05U234, 05V057, 06U069, 06U091, 08U124, 09V029, 09V047, 09V113.
03U, 04V, 09U, 10V strips numbered 284-287. All the strips labeled 288.
Pre&Post:
02PA11
Tower:
02TC04, 02TC06, 06TA03, 06TE04, 07TC05, 11TD05
Bad channels:
Pre&Post:
05PA01, 05PA02, 05PA03, 05PB10, 05PB11, 05PB12, 05PC10, 05PC11, 05PC12, 05PD10, 05PD11, 05PD12, 05PE01,
05PE02, 05PE03
11PE10, 11PE12, 11QE10, 11QE12, 11RE10, 11RE12
Tower:
11TE12, 11TE10, 10TD04, 10TD06
Note: Fifteen 05Pre1 channels have PMT problem; Swaps 11TE10<->11TE12; 10TD04<->10TD06
The procedures and results can be found here:
https://drupal.star.bnl.gov/STAR/system/files/EEMC-cal-run6%2526run9forpresentation11172014_1.pdf
All the plots are in this directory:
http://www.star.bnl.gov/protected/spin/tinglin/summber2014/run9final/
Conclusion:
Pre1, Pre2 and tower's gain decreased by 10% compared to run6;
Post shower's gain remain stable.
»