article 9 SN0016
QA from SDU
- Right side of anode wire mount apart from strongback about 5cm -- repaired at SDU
- two tapered pins extruded ~2mm beyond the side wire mount
- 5 pins of LOAB missing/broken repaired at SDU
- leakage found on 8 feed-through boards - re-epoxied
- Two fat wires used 75um BeCu wire used instead of 125 by mistake no effect from simulation by Irakli