- BEMC
- BEMC Detector Operator Manual
- Calibrations
- BPRS
- BSMD
- 1) DATA: 2008 BSMD Calibration
- 01) raw spectra
- 02) relative BSMD-E gains from 1M dAu events
- 03) more details , answering Will
- 04) bad CAP 123
- 05) BSMDE saturation, dAu, 500K minB eve
- 06) QAed relative gains BSMDE, 3M d-Au events , ver1.0
- 07) QA method for SMD-E, slopes , ver1.1
- 08) SMD-E gain equalization , ver 1.1
- 09) QA of SMD-P slopes, ver1.1
- 10) SMD-P gain equalization , ver 1.1
- 12) investigating status of P-strips
- 13) ver 1.2 : SMD-E, -P, status & relative gains, no Crate4
- 14 Eval of BSMDE status tables for pp 2008, day 49,50
- 15 stability of BSDM peds, day 47 is good
- 15a ped stability day 47, take 2
- 16) Time stability by fill of BSMD pedestals
- 17) Absolute gains , take1
- 18 Absolute gains, take 2
- 19) Absolute BSMD Calibration, table ver2.0, Isolated Gamma Algo description
- 20 BSMD saturation
- 1) M-C : response of BSMD , single particles (Jan)
- BSMD 2005 energy scale uncertainty
- Definition of absolute BSMD calibration
- Mapping, strip to tower distance
- Run 10 BSMD Calibrations
- Run 9 BSMD Calibration
- details about known hardware problems
- details of SMD simulator, simu shower zoom-in
- one cluster topology , definition of 'barrel cell'
- 1) DATA: 2008 BSMD Calibration
- BTOW - Calibration Procedure
- Run 12 BTOW Calibration
- Run 3 BTOW Calibration
- Run 4 BTOW Calibration
- Run 5 BTOW Calibration
- Run 6 BTOW Calibration
- Run 7 BTOW Calibration
- Run 8 BTOW Calibration (2008)
- Run 9 BTOW Calibration
- Database
- Hardware
- Mapping
- Service Tasks
- Software
- Useful Documents
- EEMC
- ETOF
- FCS
- FGT
- FPD & FMS & FPS
- FTPC
- FTT
- HLT
- L3
- PMD
- PP2PP
- RICH
- Roman Pot Phase II*
- SSD
- SVT
- Slow Controls
- TPC
- TRG
- Trigger Detectors
- VPD
- test
14 Eval of BSMDE status tables for pp 2008, day 49,50
Updated on Thu, 2008-08-07 11:44. Originally created by balewski on 2008-08-07 11:26.
Under:
Method:
from _private_ production w/o zero BSMD suppression we look at pedestal residua for raw spectra for minb events.
chain="DbV20080703 B2008a ITTF IAna ppOpt VFPPV l3onl emcDY2 fpd ftpc trgd ZDCvtx NosvtIT NossdIT analysis Corr4 OSpaceZ2 OGridLeak3D beamLine BEmcDebug"
The only QA was to require MPV of the spectrum is below 100, one run contains ~80K events.
Fig 1
Good spectra look like this:
Fig 2. Run 9049053, 80K events,
9,292 strips out of 15,750 tested were discarded by condition MPV>100 eve
TOP: MPV value from all strips. White means 0 (zero) counts. Crate 4 was not evaluated.
BOTTOM: status table: red=bad, white means MPV>100 events
Fig 3. Run 9050022, 80K events,
9,335 strips out of 15,750 tested were discarded by condition MPV>100 eve
TOP: MPV value from all strips. White means 0 (zero) counts
BOTTOM: status table: red=bad, white means MPV>100 events
Fig 4. Run 9050088, 80K events,
9,169 strips out of 15,750 tested were discarded by condition MPV>100 eve
TOP: MPV value from all strips. White means 0 (zero) counts
BOTTOM: status table: red=bad, white means MPV>100 events
»